Top of page. Skip to main contents. Skip to main menu. Skip to footer.

Output Range / 60Hz

Model Name M6U-G M6U2-G M8U-G
(kVA) PTA PTK PTA PTK PTA PTK
Stand-by 1200
min-1
1,600 1,685 - - 2,140 2,250
900
min-1
1,340 1,450 1,500 1,600 1,785 1,930
720
min-1
1,000 1,085 1,175 1,250 1,330 1,450
Prime 1200
min-1
1,530 1,625 - - 2,035 2,165
900
min-1
1,300 1,395 1,400 1,515 1,725 1,855
720
min-1
900 1,000 1,065 1,140 1,200 1,330
Con­tin­u­ous(C) 1200
min-1
1,365 1,460 - - 1,815 1,950
900
min-1
1,170 1,265 1,275 1,400 1,560 1,685
720
min-1
815 900 955 1,035 1,085 1,210
Con­tin­u­ous(D) 1200
min-1
1,225 1,315 - - 1,635 1,750
900
min-1
1,050 1,140 1,200 1,270 1,400 1,520
720
min-1
735 815 860 930 980 1,090
Model Name M12U-G M12U3-G M16U-G
(kVA) PTA PTK PTA PTK PTA PTK
Stand-by 1200
min-1
3,200 3,375 - - 4,280 4,500
900
min-1
2,675 2,900 3,625 3,940 3,570 3,865
720
min-1
2,000 2,175 - - 2,660 2,900
Prime 1200
min-1
3,060 3,250 - - 4,075 4,335
900
min-1
2,600 2,800 3,315 3,750 3,455 3,700
720
min-1
1,815 2,000 - - 2,420 2,660
Con­tin­u­ous(C) 1200
min-1
2,725 2,920 - - 3,635 3,900
900
min-1
2,335 2,500 3,125 3,375 3,115 3,375
720
min-1
1,630 1,815 - - 2,175 2,400
Con­tin­u­ous(D) 1200
min-1
2,455 2,630 - - 3,275 3,500
900
min-1
2,100 2,280 3,125 3,375 2,800 3,000
720
min-1
1,470 1,630 - - 1,960 2,175

Voltage Range : 60Hz 200-240V, 380-480V, 3.3kV, 4.16kV, 6.6kV, 13.8kV

  • MHI Group use the following conditions to determine the rated output of generator sets :
    Stand-by:
    Applicable for supplying emergency power at varying load in the event of normal utility power interruption. Fuel stop power in accordance with ISO15550,ISO3046-1,
    JISB8002-1,DIN6271 and BS5514.
    Prime:
    Applicable for supplying power with varying load instead of the utility for an unlimited time. +10% overload is allowed in accordance with ISO3046-1, Prime Power in accordance with ISO8528.
    Continuous(C):
    Applicable for supplying power continuously. Continuous power in accordance with ISO8528, ISO15550, ISO3046-1, JISB8002-1 and BS5514.
    Continuous(D):
    Connection to utility grid, no overload, unlimited annual operation.
  • Indicated output figures calculated in compliance with the standard ambient conditions specified by IS03046-1 (atmospheric pressure: 100 kPa, ambient temperature: 25°C, relative humidity: 30%, cooling water temperature at inlet of intake air cooler : 25°C) and based on generator efficiency of 95% at operating speed between 750 min-1 and 1200 min-1 and efficiency of 94% at 720 min-1.